Water Heater Heat-Up Time Calculator

Water heater
Temperatures
Showers

An ideal heat balance: heat losses while heating and the cold water mixing into the tank as it is drawn off are ignored, so real times are a little longer and real volumes a little smaller.

Heat-up time2.32h
Energy to heat the tank4.64kWh
Mixed water from a full tank133.33L
Heating up
Temperature rise Ts − Tc50 K
Energy E = V × c × (Ts − Tc)4.64 kWh
Heat-up time t = E ÷ P2.32 h
Heat-up time in minutes139 min
Hot water use
Mixed water at the tap temperature133.33 L
Share of stored hot water in the mix60 %
Water for one shower48.00 L
Full showers from one tank2

About this calculator

This calculator answers two everyday questions about a storage water heater (a boiler or hot water cylinder): how long does a full tank take to heat up, and how much warm water does it give. You enter the tank volume, the heating power and three temperatures – the cold mains water, the water stored in the tank, and the mixed water you use at the tap or shower.

Because hot water from the tank is mixed with cold water at the tap, a tank stored at 60 °C gives more than its own volume of water at 40 °C.

Formula

E    = V × c × (Ts − Tc) / 3600        energy, kWh   (c = 4.18 kJ/(kg·K), 1 l ≈ 1 kg)
t    = E / P                           heat-up time, h
Vmix = V × (Ts − Tc) / (Tm − Tc)       mixed water at Tm, l
showers = Vmix ÷ (flow × minutes), rounded down

V – tank volume, P – heating power, Tc – cold water, Ts – stored water, Tm – mixed water temperature.

Worked example

An 80 l cylinder with a 2 kW element, cold water 10 °C, stored at 60 °C, used at 40 °C:

E    = 80 × 4.18 × 50 / 3600 = 4.64 kWh
t    = 4.64 / 2 = 2.32 h ≈ 2 h 19 min
Vmix = 80 × 50 / 30 = 133 l of water at 40 °C
showers of 8 l/min × 6 min = 48 l → 2 full showers

FAQ

Why does a hotter tank give more water? Hotter stored water needs more cold water to bring it down to the temperature you use, so the same tank makes more mixed water. It also takes longer and more energy to heat.

Why is the real heat-up time longer? The tank loses some heat through its insulation while it heats, and an element rarely runs at exactly its rated power. The calculation is an ideal heat balance.

Can I use it for a heat pump water heater? Yes, if you enter the heat the unit puts into the water (its heating output), not the electrical power it draws.

How big a tank do I need? That depends on how many people shower or bathe in a row. Enter a size and check whether the number of showers it gives is enough.

Assumptions and limits

  • Water taken as 1 kg per litre with c = 4.18 kJ/(kg·K); the energy is within about 2 %.
  • The whole tank heats evenly from the cold water temperature; no heat losses.
  • Mixed water assumes all the stored water is drawn at the stored temperature.