Steel Beam Weight Calculator – IPE, HEA, HEB

Section
Pieces

Nominal mass from the EN 10365 dimensions at 7.85 kg/dm³; delivered beams may differ within the rolling tolerances.

Standard: LST EN 10365

Diagram
Total weight134.16kg
Weight per metre22.36kg/m
Surface to paint4.61m²
What to buy
  • Steel sections and bars134.16 kg

Rounded up to whole pieces and packs. Pack sizes come from your inputs or are typical ones — check with your supplier before buying.

Section
HHeight200 mm
BFlange width100 mm
TWWeb thickness6 mm
TFFlange thickness9 mm
Root radius12 mm
Cross-section area28.48 cm²
Weight per metre22.36 kg/m
Outer surface per metre0.768 m²/m
All pieces
Weight of one piece134.16 kg
Total length6 m
Total weight134.16 kg
Total surface to paint4.61 m²

Standards applied: LST EN 10365


About this calculator

This calculator gives the weight per metre, the total weight and the outer surface to paint of hot-rolled IPE, HEA and HEB steel beams. Pick the series and size, enter the length of one piece and how many you need.

  • IPE – the common narrow-flange I-beam, IPE 80 to IPE 600.
  • HEA – the lighter wide-flange H-beam, HEA 100 to HEA 400.
  • HEB – the heavier wide-flange H-beam, HEB 100 to HEB 400.

The dimensions are the nominal ones of LST EN 10365; the weight uses steel's 7.85 kg/dm³.

Formula

A  = 2 × b × tf + (h − 2 × tf) × tw + (4 − π) × r²      cross-section area
kg/m = A × 7850 kg/m³
U  = 2 × h + 4 × b − 2 × tw + (2π − 8) × r              outer perimeter (m² of surface per m)
total weight  = kg/m × piece length × number of pieces
total surface = U × piece length × number of pieces

h – height, b – flange width, tw – web thickness, tf – flange thickness, r – root radius between web and flange.

Worked example

One 6 m IPE 200 (h 200, b 100, tw 5.6, tf 8.5, r 12 mm):

A    = 2 × 100 × 8.5 + 183 × 5.6 + 0.858 × 144 = 2848 mm² = 28.48 cm²
kg/m = 28.48 cm² × 0.785 = 22.36 kg/m
6 m  = 22.36 × 6 ≈ 134.2 kg
U    = 400 + 400 − 11.2 − 1.717 × 12 = 768 mm → 0.768 m²/m → 4.61 m² to paint

FAQ

Why is the weight slightly different from my supplier's table? Tables round to one decimal, and rolled beams vary within their tolerances. The figure here is the nominal mass from the nominal dimensions.

Does this check whether the beam is strong enough? No. It gives weight and surface only. Choosing a beam for a load must be done by a structural engineer.

What is the paint surface? The whole outer surface of the beam – both flanges on both faces, their edges and both sides of the web – which is what a paint or fire-protection coating covers.

Assumptions and limits

  • Nominal LST EN 10365 dimensions, steel density 7.85 kg/dm³.
  • IPE 80–600, HEA 100–400, HEB 100–400.
  • Surface without the beam ends.